With the advent of graphic overrides, reflected ceiling plans are no longer a wilderness of tracing and weird hacks. What shows: • Walls • Ceiling trim and finishes • Ceiling fixtures including lights, fans, and mechanical fixtures • Floor elements, including deck edges, stairs, counters Using graphic override rules, floor elements are automatically shown dashed in RCP. And, ceiling
Several different kinds of change, which may overlap. New versions mean new workflows, and that means layer changes.
Alphabetical by name of thing. Please suggest improvements and additions. Many things have changed, many have stayed the same. Layer theory hasn't changed much. Current as of Archicad 20, which prompted some layer changes. Big table below the fold.
Alphabetical by name of thing. Please suggest improvements and additions. Many things have changed, many have stayed the same. Layer theory hasn't changed much. Current as of 16, and I'm not anticipating big differences in 17. Big table below the fold.
This is obsolete as of Archicad 15. From that version onward, renovation is the way. Read this instead. What happens when the existing model and drawings are done. The basic idea is to keep the existing conditions, both the PLN and the layout book, tucked away safely. It is theoretically possible to get existing drawings out of the addition project,
Most of the advice about sections and elevations applies to interior elevations as well. We do interior elevations because the larger scale lets us show more information. Some of this information is already in the model and the scale change reveals it. Some of it is fine modeling that doesn't need to be done until you start the interiors.
Executive summary: A new layer for elements in layouts and in the title block worksheets. There should be no elements on the Archicad layer. The Archicad layer is Archicad's own layer. It can't be deleted, hidden, or locked. Some layer then! Rare is the project element that should always show. These limitations make the Archicad layer approximately useless, and it
The reflected ceiling plan is a universal drawing type that Archicad simply does not handle very well. We took a medium-size step forward in Archicad 11 with addition of the 'Ceiling Plan' model view option for GDL objects. This allows object developers to make objects that draw themselves differently whether the 'Ceiling Plan' or 'Floor Plan' setting is active.
Location: 13 Special Construction A big dull block for subtracting a rectangular hole into a ceiling slab. Why not use a slab for an operator? Why not just draw a conventional hole in the slab? Because while the 3D block is dull, the plan symbol is rather clever, responding intelligently to the new ceiling switch in Model View Options. To
After I posted about the jellyfish a couple third-party observers commented, paraphrasing, 'Duh, of course you need to turn the hidden stuff off'. (Quick review: The issue there was clustered arrangements of elements, where AC was taking a long time to sort out the hidden lines.) Maybe so, but the last time we visited this issue, which was probably way,
There are the layer combinations for work and the layer combinations for output. In the past, the output LCs have had all their layers locked. The only reason for this was make clear to the user that they're not in a working combination. Not a critical point but there it is. Now there's a stronger reason to have the layers
In the templates for 10, I've modified the layer combinations as suggested here. There's a couple of tweaks since then. Changing the LCs is a minor change compared to changing the layers themselves, which can be very perilous. (There are a couple of layer changes in the new templates. Just a little peril!) In this theory of layer combinations, there
Alphabetical by name of thing. Please suggest improvements and additions. Note: I change the date whenever I update this, so it will pop up every now and then. Rest assured it's not all new. Big changes will have a post of their own. Updated for 10. You will see these changes in the templates when you start a project in
The Active Layer palette is accessed on a submenu of the Layers submenu, which might be on Options (9) or Document (10) or somewhere else by now. You mean the Quick Layers palette? No. Active Layer. This palette does exactly one thing, and I use it for exactly one purpose. It switches between the default state of 'Individually Set Layers'
Details need to be processed before merging them into running projects, or into a details PLN. It is important to avoid merging unwanted attributes, especially layers. This process simplifies the layers and gets rid of all the unneeded attributes. This method should be considered alongside A Method For Standard Details. Standard details will be administered by one or two people
To facilitate the creation of post-project binders.
This is obsolete as of Archicad 15 which brought new Renovation. MacDonald is a long-completed new home project. I don't know how long, but the important thing is that it's an AC7 project. We are reviving it for the purpose of some interior renovation. Naturally, we want to use the data we have. There are a few issues in working
This layer is for operator elements which you would like to show in plan. Example: You can use the filleted disc and box objects to cut a ceiling, and display those cutting elements in the plan with a dashed line. You still have to draw them over in the RCP, but two elements is better than three. Another example: A
This isn't a new layer so much as a fork of the old A Roof layer. In AC9, as everyone knows, model polygons can have a cover fill. This means generally much less drawing, and more showing of those model elements in plan. It also gives the opportunity to 'stack' model elements in plan using Display Order (Send forward/back.) In
The layer +Z Room Name is no longer with us. Dust to dust. Polvo a polvo. Room name objects in plan should go on the layer +Z Zones. This is the layer for zones of rooms. If you use zones, the stamp becomes the room name. If you don't, you can still use that layer for the object. In passing,